Is Shisha Smoking Safe While On Invasive Cardiac Stent?
Question: HI I HAD A STENT & I WAS A VERY HEAVY SHISHA SMOKER
NOW I REDUCE FROM 10 SHISHA PER DAY TO 1 SHISHA PER DAY ? IS IT OK ???
BECAUSE I TRIED TO STOP BUT I WAS LIKE CRAZY SPECIALY I AM TYPE 1 DIABETES
THE SUMMARY OF MY STENT INVASIVE CARDIAC LABORATORY:
SEVERE MID LAD 80% STENOSIS SUCCESSFULLY STENTED USING ONE DES.
RECOMMEND: DAPT/BETA BLOCKER/SATIN/CONTROL RISK FACTORS AND LIFE STYLE MODIFICATION.
CORONARY ANGIOGRAM:
LEFT CORONARY ARTERY:THE LEFT MAIN CORONARY ARTERY IS NORMAL,WITHOUT STENOSIS.
THE LEFT ANTERIOR DESCENDING CORNARY ARTERY HAS 80% STENOSIS IN MID LAD FOLLOWED BY MILD LUMINAL IRREGULARITIES DISTALLY.
THE PROXIMAL CIRCUMFLEX CORONARY ARTERY HAVE A 30% STENOSIS.
RIGHT CORONARY ARTERY:
THE RIGHT CORONARY ARTERY HAS A 30% STENOSIS PROXIMALLY WITH LUMINAL IRREGULARITIES DISTALLY.
TECHNIQUE:
CONTRAST: OMNIPAQUE 200 ML
DIAGNOSTIC CATHERTER: JL3.5/JR4 5F
GUIDING CATHETER: GUIDING EBU3.5 6F
GUIDEWIRE: XXXXXXX GUIDE WIRE X 2
BALLOON: NC QUANTUM BALLOON 3.0 MM X 8 MM
DRUG-ELUTING SENT : ONYX 2.75 MM X 30 MM
ARTERY : PROXIMAL
STENOSIS: 80%
RESIDUAL STENOSIS : 0%
STENTS: 2.75 X 30 MM ONYX RESOLUTE
TECHNIQUE: DIRECT STENTING
NOW I REDUCE FROM 10 SHISHA PER DAY TO 1 SHISHA PER DAY ? IS IT OK ???
BECAUSE I TRIED TO STOP BUT I WAS LIKE CRAZY SPECIALY I AM TYPE 1 DIABETES
THE SUMMARY OF MY STENT INVASIVE CARDIAC LABORATORY:
SEVERE MID LAD 80% STENOSIS SUCCESSFULLY STENTED USING ONE DES.
RECOMMEND: DAPT/BETA BLOCKER/SATIN/CONTROL RISK FACTORS AND LIFE STYLE MODIFICATION.
CORONARY ANGIOGRAM:
LEFT CORONARY ARTERY:THE LEFT MAIN CORONARY ARTERY IS NORMAL,WITHOUT STENOSIS.
THE LEFT ANTERIOR DESCENDING CORNARY ARTERY HAS 80% STENOSIS IN MID LAD FOLLOWED BY MILD LUMINAL IRREGULARITIES DISTALLY.
THE PROXIMAL CIRCUMFLEX CORONARY ARTERY HAVE A 30% STENOSIS.
RIGHT CORONARY ARTERY:
THE RIGHT CORONARY ARTERY HAS A 30% STENOSIS PROXIMALLY WITH LUMINAL IRREGULARITIES DISTALLY.
TECHNIQUE:
CONTRAST: OMNIPAQUE 200 ML
DIAGNOSTIC CATHERTER: JL3.5/JR4 5F
GUIDING CATHETER: GUIDING EBU3.5 6F
GUIDEWIRE: XXXXXXX GUIDE WIRE X 2
BALLOON: NC QUANTUM BALLOON 3.0 MM X 8 MM
DRUG-ELUTING SENT : ONYX 2.75 MM X 30 MM
ARTERY : PROXIMAL
STENOSIS: 80%
RESIDUAL STENOSIS : 0%
STENTS: 2.75 X 30 MM ONYX RESOLUTE
TECHNIQUE: DIRECT STENTING
Brief Answer:
My suggestion.
Detailed Answer:
Hi,
I would like to know whether you are experiencing any kind of withdrawal symptoms like sweating, nervousness, headache.
If not you can continue with 1 shisha.
Regarding your cardiac reports, please consult your cardiologist.
Hope I have answered your query.
Take care
Regards,
Dr Soujanya, Psychiatrist
My suggestion.
Detailed Answer:
Hi,
I would like to know whether you are experiencing any kind of withdrawal symptoms like sweating, nervousness, headache.
If not you can continue with 1 shisha.
Regarding your cardiac reports, please consult your cardiologist.
Hope I have answered your query.
Take care
Regards,
Dr Soujanya, Psychiatrist
Note: In case of any other concern or query related to prevention, evaluation, diagnosis, treatment, or the recovery of persons with the any type of addiction or substance use, follow up with our Addiction Medicine Specialist. Click here to book a consultation now.
Above answer was peer-reviewed by :
Dr. Prasad