What Does My ECG Report Indicate?
My pr interval was 194
My arsenal was 94
Qt/qtc was380/404
Prt axes says * 145 166
Normal sinus rhythm
Seems my prt is missing a first number and the second two are way high. What does this mesn
Your ECG is technically not right
Detailed Answer:
Hello Ma'am, I've reviewed the attached report,
After going through the details provided by you I would like to tell you that there is a probable technical error in your ECG which makes it a technically incorrect.
Here is why I am saying this:
1. In your ECG lead I is negative, I mean P wave QRS complex T wave all are inverted. It happens in two scenarios that either a technical fault or the heart is on the right side. A technical fault is more common.
2. There is a right axis deviation.
3. aVR lead is positive.
All these conditions go in favor of a technical error which is known as arm lead reversal i.e. by mistake the right arm lead was kept on the left arm or vice versa.
I would like to advise you to personally consult your doctor and confirm the same.
Feel free to ask back if you have any more doubts.
Kind regards
Dr. Bhanu Partap